Flowserve 025000 Series Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 10
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
9
Flow Control Division
Kammer Control Valves
11.00
Hex bolt Waisted bolt Studs
Thread DIN 933 DIN 2510 DIN 939
A2-70 1.7709 1.7258 CK 35
M 8 20 Nm
M 10 35 Nm 20 Nm
M 12 60 Nm 44 Nm 36 Nm 35 Nm
M 16 145 Nm 115 Nm 92 Nm 80 Nm
M 20 280 Nm
M 24 250 Nm 270 Nm
4.2.11 Using torque wrench, gradually tighten all bolts alter-
nating crosswise to following torques (see following
table).
Note: When the housing bolts are tightened, the halves
of the housing must always be parallel (see fig. 5).
4.2.12 Replace packing by inserting packing rings one at a
time tapping each one down with a suitable bushing.
IMPORTANT: ensure that the gaps in the packing
rings are distibuted evenly around the circumferance
in the packing box (gaps not in line).
Note:
different packings and fitting sequence is shown
in the spare parts list.
6.1.13 Insert packing follower. Fit gland nut for transport
purposes only. Gland nut to be fitted correctly and
tightened down when actuator is mounted.
4.2.14 When performing subsequent pressure test, note the
max. permissible pressure for the bellows. After the
check for leaks, close off test connection with plug or
suitable gauge.
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10

Comentarios a estos manuales