Flowserve DFP17 Manual de usuario Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
26 DataFlo Digital Electronic Positioner DFP17 Installation, Operation and Maintenance Instructions WCAIM2037
5.0 TECHNICAL DATA
5.1 Allowable Supply Voltage Range
All Voltages ±10%
Power Consumption (Circuit Board Only): 2.5 Watts
5.2 Input Circuit Specifications
Maximum Tolerated Noise Level at Maximum Positioner
Resolution/Sensitivity Approx. 3.5 mV (16 microamps)
Resistance Input
DFP-1K Nom. 1000 ohms
DFP-13 Nom. 135 ohms
Current Input
DFP-1 1 to 5 mA
DFP-4 4 to 20 mA
DFP-10 10 to 50 mA
Voltage Input
DFP-5V 0 to 5 VDC
DFP-XV 0 to 10 VDC
5.3 Output Circuits Specifications
All Models
Maximum Surge Current 100 A for 1 Cycle
Maximum Normal Starting or
In-Rush Current 10 A for 1 Second
Maximum Stall Current 8 A for 1 Minute
Maximum Running Current - Resistive Load 5 A
90% Duty Cycle
Maximum Running Current - Inductive Load 3 A
90% Duty Cycle
Maximum Peak Voltage at Load Circuit
(All 120 VAC and 240 VAC models) 800 VAC
Maximum Driver Circuit Current
(All 12 VDC and 24 VDC Models) 3 A Continuous
4-20 mA output will drive 20 mA into a 600 ohm maximum load.
Alarm Output - 100 mA maximum at 50 volts DC maximum.
5.4 Input Circuit Load Resistances
1 to 5 milliamp models Approx. 1000 ohms
4 to 20 milliamp models Approx. 220 ohms
10 to 50 milliamp models Approx. 100 ohms
0 to 5 VDC Models Approx. 800 ohms
0 to 10 VDC Models Approx. 1100 ohms