37-1Valtek No. 35190
Valtek Valdisk 150
Control Valves
NOTE: Selecting the proper fastener material is the
responsibility of the customer. Typically, the supplier
does not know what the valve service conditions or
environment may be. Valtek‘s standard bolting material
is B7/2H. B8 (stainless steel) is optional for applications
above 800
O
F and with stainless steel or alloy body
valves. The customer therefore must consider the
material’s resistance to stress corrosion cracking in
addition to general corrosion. As with any mechanical
equipment, periodic inspection and maintenance is
required. For more information about fastener materi-
als, contact your local Valtek representative or factory.
Unpacking
1. While unpacking the valve, check the packing list
against the materials received. Lists describing the
valve and accessories are included in each shipping
container.
2. When lifting the valve from the shipping container,
position lifting straps to avoid damage to tubing and
mounted accessories. Most Valdisk 150 valves
may be lifted by the actuator lifting ring. If no lifting
ring is provided, lift the valve using lifting straps or
hook through the yoke legs and outer end of the
body.
3. In the event of shipping damage, contact your ship-
per immediately.
4. Should any problem arise, contact your Valtek rep-
resentative.
GENERAL INFORMATION
The following instructions are designed to assist in
unpacking, installing, operating and performing mainte-
nance as required on Valdisk 150 butterfly valves.
Product users and maintenance personnel should thor-
oughly review this bulletin prior to working on the valve.
Separate maintenance instructions cover additional fea-
tures (such as positioners, special accessories, fail-
safe systems,etc.)
This publication does not contain information on install-
ing, maintaining, troubleshooting, calibrating, and oper-
ating Valtek actuators or positioners. Refer to the
appropriate Valtek Installation, Operation, Maintenance
Instructions when this information is required.
To avoid possible injury to personnel or damage
to valve parts, WARNING and CAUTION notes
must be strictly adhered to. Modifying this prod-
uct, substituting nonfactory parts, or using
maintenance procedures other than outlined
could drastically affect performance, be hazard-
ous to personnel and equipment, and may void
existing warranties.
WARNING: Standard industry safety practices must
be adhered to when working on this, or any other,
process control product. Specifically, personal
protective and lifting devices must be used as war-
ranted.
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - Control Valves

37-1Valtek No. 35190Valtek Valdisk 150Control ValvesNOTE: Selecting the proper fastener material is theresponsibility of the customer. Typically, the

Pagina 2 - Installation

37-2TABLE I:Flange Bolting Torques* (Class 150) Torque Values(ft-lbs) (newton-meter)2, 3, 4 118 1606, 8 209 28210, 12 337 455* For intermediate str

Pagina 3 - Figure 1: Body Assembly

37-3Body Packing Retainer (Item No. 85) Packing (Item No. 88) Shaft (Item No. 51)Packing Box Nut (Item No. 117)Gland Flange (It

Pagina 4 - DISASSEMBLY AND REASSEMBLY

37-4Figure 2: Typical Packing Configuration4. Slide the valve carefully from the line. To avoiddamage to gasket surfaces, do not twist the valve.5. A

Pagina 5 - Reassembling the Body

37-5Disassembling the BodyTo disassemble the Valdisk 150 body, refer to Figures1 and 3 and proceed as follows:1. Lay the valve body on a flat surface

Pagina 6 - Remounting Valve to Actuator

37-615. Rotate disc several times to allow seat to self-cen-ter in the body. Again, check packing box nuts to becertain they are tight, per step numbe

Pagina 7

37-7Failure Probable Cause Corrective ActionValve moves to failure 1. Failure of actuator O-ring 1. Replace actuator stem O-ringposition, excessive ai

Pagina 8

Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, thisFlowserve produc