Flowserve ISC1BX Manual de usuario Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
2 Disassembly
When disassembling seal, inspect for conditions which may have caused the
need for the seal to be removed from service. If seal was removed due to
premature failure, determine what conditions caused that failure and correct any
problems prior to returning the repaired seal to service. For assistance with seal
failure analysis, please contact your Flowserve representative.
2
© Copyright 2000 Flowserve Corporation
These instructions are written for trained, experienced technicians familiar with the basic
principles and tools involved in the installation, care and service of mechanical seals and seal
support systems. A complete reading of these instructions by personnel in contact with the
equipment is essential to safety. Incorrect installation, operation or maintenance can result in
personal injury or death to personnel and damage to the equipment.
1 Nomenclature
Note: Primary seal O-rings (P and 6) are
the same size and cross section.
34 Bellows Assembly
3A Mating Ring
P Mating Ring O-Ring
6 Bellows O-Ring
11 Sleeve O-Ring
G Gasket
1 Gland Assembly
1B Gland Drive Ring
CT Centering Tab
K Centering Tab Cap Screw
SL Sleeve Assembly
M Vibration Dampener
M1 Bellows Vibration Dampener
10A Driver Ring
9 Sleeve Collar
13 Cup Point Set Screw
13A Quarter Dog Set Screw
Table 1
Figure 1
Seal Parts that are always replaced
Bellows Assembly 34
Mating ring 3A
All O-rings P , 6 , 11
Gland gasket G
Vibration dampener M
Bellows Vibration dampener M1
Centering tabs CT and cap screws K
Cup point and quarter dog set screws 13 and 13A
Reconditionable Seal Parts
Gland assembly 1
Sleeve assembly SL
Sleeve collar 9
G
SL
M
M1
3A
1 13910A
11
6
34 P
K 13A
CT1B
Vista de pagina 1
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios