NRS 1-8
Technical Data
Type approval no.
09 - 91 - 0112
Input
Four terminals for the connection of one level electrode
NRG 16-12, PN 40
NRG 17-12, PN 63
NRG 19-12, PN 160
Output
Two volt-free relay contacts (mounted in series in the case of design “b").
Max. contact rating: 250 V, 300 W, 3 A resistive with a life of 5 x 10
5
switching cycles of 0.35 A
inductive with a life of 2 x 10
6
switching cycles. Contact material silver, hard-gold plated.
Delay of response
Default factory setting: 3 s
(Up to 25 s possible after prior consultation with TÜV)
Sensitivity
10 µS/cm at 25 °C when used in conjunction with level electrode without measuring surface
extension (cell constant C = 0.3).
0.5 μS/cm at 25 °C when used in conjunction with level electrode with measuring surface
extension (cell constant C = 0.13) – see data sheet “NRG 16-12”.
Indicators and adjustors
2 LEDs “Alarm”, 1 LED “Power”, 1 button “TEST 1”,
1 switch “TEST 2 / INSPECTION”.
Mains supply
230 V +/- 10 %, 50/60 Hz (please state voltage when ordering).
Special voltage: 115 V +/- 10 %, 50/60 Hz or 24 V +/- 10 %, 50/60 Hz.
The ancillary unit URN 1 can be used for 24 V d. c. supply.
Power consumption
5 VA
Protection
NRS 1-8 IP 40 to EN 60529
Admissible ambient temperature
0 °C to 55 °C
Case materials
Base: Noryl SE 1-GFN 2 UL 94 VO, black
Cover: R-ABS UL 94 VO, stone grey
Weight
Approx. 0.6 kg