GESTRA Steam Systems
TRG 5-6x
Installation Instructions 818597-00
Temperature Sensors TRG 5-63, TRG 5-64
Temperature Sensors TRG 5-65, TRG 5-66
Temperature Sensors TRG 5-67, TRG 5-68
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - TRG 5-6x

GESTRA Steam SystemsTRG 5-6xInstallation Instructions 818597-00Temperature Sensors TRG 5-63, TRG 5-64 Temperature Sensors TRG 5-65, TRG 5-66 Temperatu

Pagina 2 - Contents

10Technical Data– continued –Dimensions TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68Fig.4EFG© 1114084L17/24 A. F.[mm]115140200200L[mm]25 252525DEFG[mm]18

Pagina 3

11Functional ElementsTRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68KeySealing surfaceJoint ring ©13x26Temperature sensitive lengthThrea

Pagina 4 - Important Notes

12InstallationTRG 5-63 and TRG 5-641. Clean sealing surfaces .2. Put joint ring onto the sealing surface (make sure that the material of the joint r

Pagina 5 - Explanatory Notes

13Installation– continued –Examples of InstallationKeyProtection tube / welding sleeveElbowThermal insulationFig.8Fig.9Fig.6Fig.7LMML100100NLMN

Pagina 6

14WiringTRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68Use screened four-core cable for wiring, e. g. Ölflex 110 CH, produced by Lapp, 4

Pagina 7

15Wiring– continued –Wiring diagramAdditional indicating devices can be connected to the terminals marked in yellow and black of the TRG 5-64, and TRG

Pagina 8

16CommissioningCheck wiringCheck that the temperature sensor TRG 5-6x and its associated temperature transmitter TRV 5-40 have been wired in accordanc

Pagina 9

17OperationTRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68Operation in conjunction with temperature transmitter TRV 5-40 in (pressurised

Pagina 10 - Technical Data

18MaintenanceSpare partsReplace measuring elementThe measuring element can be replaced during operation if necessary. 1. Switch off bus supply voltag

Pagina 11 - Functional Elements

19AnnexDecommissioningRisk of severe burns and scalds to the whole body! Before removing the temperature sensor make sure that the vessel or the pipe

Pagina 12 - Installation

2ContentsPageImportant NotesUsage for the intended purpose...

Pagina 13

818597-00/905agt ©2005 GESTRA AG Bremen Printed in Germanywww.gestra.deGESTRA AGPostfach 10 54 60, D-28054 Bremen Münchener Str. 77, D-28215 Bremen T

Pagina 14

3ContentsPageCommissioningCheck wiring ...

Pagina 15 - – continued –

4Important NotesUsage for the intended purposeUse temperature sensors TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68 only in con-juncti

Pagina 16 - Commissioning

5Explanatory NotesScope of supplyTRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67, TRG 5-68 1 Temperature sensor 1 Installation manualSystem descripti

Pagina 17 - Malfunctions

6Technical DataTRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68Measuring element (3-wire connection) TRG 5-63 1x Pt 100 to EN 60751, clas

Pagina 18 - Maintenance

7Technical Data– continued –TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68– continued –Materials TRG 5-63, TRG 5-64 Protection tube 1.4

Pagina 19

8Technical Data– continued –Corrosion resistanceIf the equipment is used for the intended purpose, its safety is not impaired by corrosion.SizingThe h

Pagina 20 - GESTRA AG

9Technical Data– continued –Dimensions TRG 5-63 and TRG 5-64Fig.2N8N100.5½" BSP to DIN 228-1© 26Fig. 315© 26© 9120 84© 9A. F. 27½" BSP to DI