23
Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14
flowserve.com
Performance Specifications
Actuator
Output
Torque
(Continuous
Start/Run
Torque)
Stall
Torque
(1.25X)
Cycle Time
(90°)
24VDC
120/240VAC
Output
Speed
24VDC
120/240VAC
Full Load Amps
Version
Platform
(PF)
Model
Units Nm (in-lbs) Nm (in-lbs) Sec. RPM 24VDC 120/VAC 240VAC
Standard
On/Off
Modulating
PF1
M15 17 (150) 21 (187) 5 3 0.8A 0.15A 0.08A
M60 68 (600) 85 (750 5 3 2.1A 1.0A 0.49A
M150 169 (1500) 211 (1875) 10 1.5 4.2A 1.4A 0.75A
PF2
M250 282 (2500) 422 (3125) 16 0.9 6.5A 1.6A 0.85A
M500 565 (5000) 706 (6250) 33 0.5 6.5A 1.6A 0.85A
Materials of Construction
Component Material
Housing and Cover Die cast aluminum
Aluminum surface treatment Non-chrome conversion coating
Worm Gear set Ductile iron (M15, M60), Bronze (M150, M250, M500)
Output Drive Ductile iron
Baseplate ISO 5211, F05/07, FA05/07
Paint
Polyester powder coat
Salt Spray: ASTM B117, 1050 hrs.
Technical Data
Voltage Rating 120/240 VAC/VDC; 12*/24 VDC; Single (and optional 3-phase)
Temperature -40C to +70C, low temp. option -48C
Environmental
Type 4, 4X,6, IP66/68 (3m for 48hrs)
Class 1, Div 1,2, Gps B,C,D (CSA,FM)
ATEX II 2G Ex d IIB +H2 T4: IECEx II 2G Ex d IIB +H2 T4
Vibration Testing IEC60068-2-6 Appendix B
CE Declaration Low voltage, EMI/EMC approval
Weight M15/60: 24 lbs (10.9kgs) M150: 25.5 lbs (11.6kgs)
* For 12VDC, consult factory
6. Performance and Technical Data