Figure 17: Driver Module Barbed Fitting
10. Disconnect the flexible tubing from the barbed fitting at
the driver module assembly (see Figure 17).
11. Use the 1/4" nutdriver to remove the barbed fitting
from the driver module assembly.
12. Unplug the two wiring connections that link the driver
module assembly to the main PCB assembly.
13. Feed the two wires on the driver module back into the
driver module compartment so that they stick out the
driver module opening (see Figure 14). This will allow
the driver module to thread out without tangling or
cutting the wires.
14. Grasp the base of the driver module and turn it
counterclockwise to remove. After it is threaded out,
carefully retract the driver module from the housing.