4
1.10Pressure testing of the ST/QBM, ST/MRA, ST cartridge
canister dual seal prior to installation is possible but not
necessary.Ifpressuretestingisdesiredthenpressuretest
at1.7bar(25psig)butnevermorethan3.4bar(50psig)with
dry nitrogen or instrument air. Prior to testing Flowserve must be
consultedtodetermineacceptablegasleakagerates.Ifbench
testing is desired the tests may be conducted if and only if
Flowserve has been consulted regarding the safety of testing
thesealcanisteronthebench.Benchtestsafetyissuesmay
exist and cause physical injury and damage.
Caution:Benchtestpressurenevertoexceed3.4bar(50psig)
2 ST/QBM, ST/MRA, ST Cartridge Seal Installation
Tools needed:
• Open end wrenches for nuts or bolts
• Allen wrenches for cap screws and set screws
• LubricantforO-rings
2.1 Attach the seal housing to vessel ange and/or gear box.
Each bottom entry mixer may have a different procedure for
attaching the seal and mixer drive to the vessel. Follow the
assembly instructions and recommendations of the manufac-
tureroftheequipment.DoNOTusethesealcanisterpiping
to lift and handle the seal.
2.1.1 Lubricate the shaft and ange bores over which O-rings
will slidewithanappropriateapprovedlubricant.TheSTline
of seals is typically used in bioprocessing applications where
onlydeionizedwaterisanacceptablelubricant.However,
because of the poor lubricating properties of deionized water
it is recommended that a better lubricant be used if possible.
2.1.2 Line up the shaft with the seal cartridge sleeve. Theseal
canisterwillbeattachedtothebottomofthevesselangeORto
thegearboxandvesselange.Ineithercasetheshaftmustbe
slid through the center of the seal cartridge from a position above
theseal.Thispositioncancontributetobindingand/ortwistingof
the seal sleeve as the shaft moves through it. Note:Iftheseal
canisterisattachedtoa90°gearbox,theweightofthemotor
off-settoonesideputsalargetorqueonthesealcanisterwhich
maydistortthecanisterthatistintothemixerange.