• no aux. energy supply (
pneumatic air or electrical power
) to actuator and accessories (
solenoid valve, filter reducing
station, positioner, limit switch
and special accessories )
• the fitted accessories do not
work
• the pneumatic actuator is
defective
• the electrical actuator is
defective
• excessive tightening of the
stuffing box packing
• Valve trim worn, stuck
• pneumatic actuators: check supply
line for leaks; check pressure (
usually 6 bar )
• electrical actuators: check power
supply (connections, circuit breakers,
voltage)
• see maintenance and operating
instructions of accessories
manufacturer
• contact customer service
departement or contract partner
• see maintenance and operating
instructions of actuator manufacturer
• loosen stuffing box packing nuts until
valve operates properly
Caution: make sure there are no leaks !
• contact customer service
departement or contract partner
• dirty spindle
• damaged spindle
• actuator not powerful enough
•
clean spindle with suitable cleaning
agent
• contact customer service department
or a contract partner
• compare actuator specs on the
rating plate with operation
specifications of the facility - if
incompatible, contact customer
service department or contract
partner
Spindle travel less than full
stroke
( 0 to 100% stroke )
• air supply pressure too low
• pneumatic actuators: bad hand
wheel position (hand wheel
emergency operation)
• electrical actuators: limit switch
misadjusted
• badly adjusted or defective
positioner
• foreign particles in valve seat,
damaged trim
• provide air at the pressure stated on
the rating plate
• take hand wheel to limit position
• readjust limit switch to actuator manu
facturer`s specifications
• readjust positioner to positioner
manu facturer`s specifications
• contact customer services
department or contract partner
Comentarios a estos manuales