WDX USER INSTRUCTIONS ENGLISH 71576322 06-05
Page 38 of 46
®
7 FAULTS; CAUSES AND REMEDIES
FAULT SYMPTOM
Pump ov erheat s and s eize s
Bearing s h av e sh ort l if e
Pump v ib rat es or is noi s y
M ech an ic al se al ha s short lif e
M ech an ic al se al l ea ks ex ce ssiv el y
Pump requir es ex ces siv e po wer
Pump lose s prim e af t er st art ing
In su f f icient pre ssu r e dev elop ed
In su f f icient c apac it y del iv ered
Pump does n o t de liv er liqu id
PROBABLE C AUSES POSSIBLE REMEDIES
A. System troubles
Pump not primed.
Pump or suction pipe not compl etel yfilled with
liquid.
Checkcomplete filling. Vent and/or prime.
Suction lift too high or level too low.
Insufficient margin between suction pr essure and
vapour pressure.
CheckNPSH
A
>NPSH
R
, proper submergence,
losses at strainers and fittings.
Excessive amount of air or gas in liquid. Checkand purge pipes and system.
Air or vapour pocket in suction line. Checksuction line design for vapour pockets.
Air leaks into suction line. Checksuction pipe is airtight.
Air leaks into pump through mechanical seal,
sleeve j oints, casing joint or pi pe plugs.
Checkand r eplace faulty parts.
CONSULT FLOWSERVE.
Foot valve too small. Investigate replacing the foot valve.
Foot valve partiall yclogged. Clean foot valve.
Inlet of suction pipe insufficientlysubmerged. Checkout system design.
Speed too l ow. CONSULT FLOWSERVE.
Speed too high. CONSULT FLOWSERVE.
Total head of system higher than differential head
of pump.
Total head of system l ower than pump design
head.
Checksysteml osses.
Remedyor CONSU LT FLOWSERVE.
Specific gravity of liquid differ ent from design.
Viscosity of liquid differs from that for which
designed.
Checkand CONSULT FLOWSERVE.
Operation at very low capacity.
Measure value and chec k minimum permitted.
Remedyor CONSU LT FLOWSERVE.
Operation at high capacity.
Measure value and chec k maximum per mitted.
Remedyor CONSU LT FLOWSERVE.
B. Mechanical troubles
Misalignment due to pipe str ain.
Checkthe flange connections and eliminate strai ns
using elastic couplings or a method permitted.
Improperl ydesigned foundation.
Checksetting of baseplate: tighten, adjust, grout
base as required.
Shaft bent.
Checkshaft runouts are within acceptable values.
CONSULT FLOWSERVE.