1 USING KÄMMER VALVES AND ACTUATORS
CORRECTLY
1.1 General
The following instructions are designed to assist in
unpacking, installing and performing maintenance as
required on Kämmer products. Product users and
maintenance personnel should thoroughly review this
bulletin prior to installing, operating or performing
any maintenance.
DANGER:
In most cases Kämmer valves and actuators
are designed for specific applications (e.g. with regard
to medium, pressure, temperature). For this reason
they should not be used in other applications without
first contacting the manufacturer.
1.2 Terms concerning safety
The safety terms DANGER, WARNING, CAUTION and
NOTE are used in these instructions to highlight
particular dangers and/or to provide additional
information on aspects that may not be readily
apparent.
DANGER:
indicates that death, severe personal injury
and/or substantial property damage will occur if
proper precautions are not taken.
WARNING:
indicates that death, severe personal injury
and/or substantial property damage can occur if
proper precautions are not taken.
CAUTION:
indicates that minor personal injury and/
or property damage can occur if proper precautions
are not taken.
Index
1 Using Kämmer valves and actuators correctly.
2 Unpacking
3 Installation
4 Quick check
5 Maintenance
6 Remove and install actuator
7 Disassemble and assemble valve
8Trouble-shooting chart
NOTE:
indicates and provides additional technical
information, which may not be very obvious even to
qualified personnel. Compliance with other, not
particularly emphasised notes, with regard to
transport, assembly, operation and maintenance and
with regard to technical documentation (e.g. in the
operating instruction, product documentation or on
the product itself) is essential, in order to avoid faults,
which in themselves might directly or indirectly cause
severe personal injury or property damage.
1.3 Protective clothing
Kämmer products are often used in problematic
applications (e.g. extremely high pressures, dang-
erous, toxic or corrosive mediums). In particular
valves with bellows seals point to such applications.
When performing service, inspection or repair
operations always ensure, that the valve and actuator
are depressurised and that the valve has been cleaned
and is free from harmful substances. In such cases
pay particular attention to personal protection
(protective clothing, gloves, glasses etc.).
1.4 Qualified personnel
Qualified personnel are people who, on account of
their training, experience and instruction and their
knowledge of relevant standards, specifications,
accident prevention regulations and operating
conditions, have been authorised by those responsible
for the safety of the plant to perform the necessary
work and who can recognise and avoid possible
dangers.
1.5 Installation
DANGER:
Before installation check the order-no,
serial-no. and/or the tag-no. to ensure that the valve/
actuator is correct for the intended application.
Do not insulate extensions that are provided for hot
or cold services.
Pipelines must be correctly aligned to ensure that the
valve is not fitted under tension.
STOP!
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - Standard Valves

1Flow Control DivisionKammer Control ValvesInstallation, Operation, Maintenance InstructionsStandard ValvesSeries 035 000 Globe ValvesSeries 031 000 A

Pagina 2 - Flow Control Division

2Flow Control DivisionKammer Control Valves2 UNPACKING2.1 Each delivery includes a packing slip. When unpack-ing, check all delivered valves and acces

Pagina 3

3Flow Control DivisionKammer Control Valvessure exceeds the pressure specified on the nameplate,a pressure reducing station is required. If instrument

Pagina 4 - Actuator series 2

4Flow Control DivisionKammer Control ValvesCouplingCoupling screwsCoupling insertLocknutYoke plateYoke nutsActuator series 2Fig. 1aZero adjustment loc

Pagina 5

5Flow Control DivisionKammer Control Valves6 REMOVE AND INSTALL ACTUATORGeneral InformationWe recommend separating the actuator from thevalve during a

Pagina 6

6Flow Control DivisionKammer Control ValvesPacking kit seespare parts listTrim seespare parts listLocknutGland nutPacking followerClamping nutNutBonne

Pagina 7

7Flow Control DivisionKammer Control Valves6.4.3 Unscrew the coupling insert until the yoke rods areraised from the lower yoke plate by around 2 mm.NO

Pagina 8 - 8 Trouble-shooting Chart

8Flow Control DivisionKammer Control Valves8 Trouble-shooting ChartFault Possible Cause RemedyStem motion 1. Packing excessively tightened 1. Tighten