3
Mixer/Agitator Shaft and Flange Requirements Figure 1
1.10 Pressure testing of this cartridge canister dual seal prior to
installation is possible using ltered dry nitrogen or instrument air.
Consult Flowserve, Flow Solutions for acceptable gas leakage rates
for this seal design.
To rst obstruction
(See assembly drawing)
Face of vessel ange to
be square to the axis of
the shaft to within 0.25 mm
(0.010 inch) FIM and have
a √1.6 µm (63 µinch) Ra
nish or better
Bearings, drive, and coupling must be in good condition
Maximum vertical shaft movement (axial end play) = 0.61 mm (0.024 inch) FIM
Maximum static vessel ange out of concentricity = 0.50 mm (0.020 inch) FIM
Maximum static vessel ange to shaft out of squareness = 0.25 mm (0.010 inch) FIM
Maximum dynamic shaft deection = 3 mm (0.125 inch) FIM
The MD-200 Seal design may include an optional radial bearing in
the canister to protect the seal from excessive shaft runout or whip.
Shaft OD to be +0.025 mm
(+0.001 inch)
-0.025 mm
(-0.001 inch)
with a surface nish of √ 0.8 µm
(32 µinch) Ra or better