3
Mixer/Agitator Shaft and Flange Requirements Figure 1
1.10 Pressure testing of this cartridge canister dual seal prior to
installation is possible using ltered dry nitrogen or instrument air.
Consult Flowserve, Flow Solutions for acceptable gas leakage rates
for this seal design.
To rst obstruction
(See assembly drawing)
Face of vessel ange to
be square to the axis of
the shaft to within 0.25 mm
(0.010 inch) FIM and have
a √1.6 µm (63 µinch) Ra
nish or better
• Bearings, drive, and coupling must be in good condition
• Maximum vertical shaft movement (axial end play) = 0.61 mm (0.024 inch) FIM
• Maximum static vessel ange out of concentricity = 0.50 mm (0.020 inch) FIM
• Maximum static vessel ange to shaft out of squareness = 0.25 mm (0.010 inch) FIM
• Maximum dynamic shaft deection = 3 mm (0.125 inch) FIM
The MD-200 Seal design may include an optional radial bearing in
the canister to protect the seal from excessive shaft runout or whip.
Shaft OD to be +0.025 mm
(+0.001 inch)
-0.025 mm
(-0.001 inch)
with a surface nish of √ 0.8 µm
(32 µinch) Ra or better