PB DPV1 / PA Field Unit Installation and Maintenance FCD LMENIM2336-03 – 12/12
20
2.2.5 Network Cabling for PROFIBUS PA
Network cabling should be in accordance with PROFIBUS Process Automation (PA) guidelines using
twisted-pair shielded cable. The data line is normally also used to supply power to the field devices.
PROFIBUS PA is a combination of the PROFIBUS-DP V1 protocol and the IEC 61158-2 transmission
technique.
The following items should be taken into account when planning the network:
• Transmission rate – Within a network, only one transmission rate can be used; typical restrictions
of PA are 31.25kbits/sec.
• The required number of nodes.
• The type of network components needed – Terminals, connectors, connecting cables, termination.
• The type of cable to be used and its characteristics.
• The number of segments and/or repeaters.
• The overall span of the network – Adding repeaters and long cable lengths can increase transmis-
sion time.
• Cable termination – Active termination resistors are required at the ends of all segments.
Tables 2.5 and 2.6 detail the recommended cable parameters and various types of cable that can be
used for network cabling. For additional guidelines, see the following publications:
• PROFIBUS Networks SIMATIC NET 6GK1970-5CA20-0AA1
• Technical Guideline – PROFIBUS PA User and Installation Guideline Version 2.2 February 2003,
PROFIBUS Guideline Order No. 2.092
Table 2.5 – Recommended PROFIBUS PA Cable Parameters (Type A – shielded twisted-pair)
Characteristic impedence 100 ohms ±20%
Maximum capacitance 2 nF/km
Loop resistance 44 ohms/km
Conductor cross-sectional area 0.8 mm
2
(AWG 18)
Maximum length of network (including spurs) 1900 m
Table 2.6 – Recommended PROFIBUS PA Cable Types
PA, Ex and Non-Ex
(ABB Automation Products GmbH)
NPC080-NO
PA, Ex and Non-Ex
(ABB Automation Products GmbH)
NPC150-NO
PROFIBUS FC Process Cable (Siemens AG) 6XV1 830-5.H10
PROFIBUS Data Cable (Beldon Wire & Cable) 3079A & 3076F
UNITRONICS Bus PA (Lapp Kabel GmbH) 2170 235 1x2x1.0
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 87 88

Comentarios a estos manuales

Sin comentarios

Corel LCCDGSX6ML3 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Oprogramowanie graficzne Corel LCCDGSX6ML3.
Dostarczamy 1 pdf podręczników Corel LCCDGSX6ML3 do pobrania za darmo według typów dokumentów: Arkusz Danych


Corel LCCDGSX6ML3 Arkusz Danych (11 strony)


Marka: Corel | Kategoria: Graphics software | Rozmiar: 1.51 MB |

 

Spis treści





Więcej produktów i instrukcji dla Oprogramowanie graficzne Corel

Modele Rodzaj dokumentu
LCCDGSX4ENA Arkusz Danych   Corel DRAW Graphics Suite X4, Home & Student, 32 strony
CDGSX5CZPLHBB Arkusz Danych   Corel CDGSX5CZPLHBB, 9 strony
KO2ENGPCM Arkusz Danych   Corel KnockOut 2, 2 strony
Painter 2015 Podręcznik Użytkownika   Corel Painter 2015, 968 strony
PaintShop Pro X7, DE Podręcznik Użytkownika   Corel PaintShop Pro X7 Ultimate, 857 strony
CDGSX7DEDBUG Dokumentacja   Corel CorelDRAW Graphics Suite X7, CZ/PL, 37 strony
Painter X3 Win/Mac, EDU, EN Podręcznik Użytkownika   Corel Painter X3, EN, 943 strony
PaintShop Pro X6 Ultimate Podręcznik Użytkownika   Corel PaintShop Pro X6 Ultimate, EN, 224 strony
CAD 2014 Dokumentacja   Corel CAD 2014, 21 strony
Painter 12, WIN, MAC, 251-350u Arkusz Danych   Corel Painter 12, WIN, MAC, 11-25u, MLNG, 26 strony
PaintShop Pro X4 Podręcznik Użytkownika   Corel PaintShop Pro X4 User guide, 194 strony