Flowserve PA46 Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
20
Maintenance  continued 
Replacing stuffing box MPA 46, MPA 47
1. Detach pressure line for the control fluid of the diaphragm actuator from the screwed socket
Z.
2. Remove diaphragm actuator
Y. Fig. 4
3. Remove spacer disk
X and pressure plate V.
4. Unscrew hexagonhead cap screws
W.
5. Remove pressure plate
V and mounting bracket B.
6. Pull out split pin
S.
7. Use openend spanner A. F. 28 mm to unscrew the pressure pin
R from the valve plug D.
8. Remove compression spring
P.
9. Use openend spanner A. F. 32 mm to unscrew the union nut
O.
10. Unscrew sealing plug
G and remove gasket F.
11. Pull out valve plug
D.
12. Take out internal parts
N M L K L J of stuffing box.
13. Clean stuffing box, valve body and valve plug.
14. Reinsert valve plug
D and use abrasive paste type TETRABOR
®
F400 for polish grinding.
15. Insert new gasket
F and screw in sealing plug G. Tighten with a torque of 350 Nm.
16. Reinsert internal parts of stuffing box according to order as specified on page 24.
Fig. 5, Fig. 6
17. Apply heatresistance lubricant to stuffing box thread (use e.g. WINIX
®
2150).
18. Align valve plug
D such that the hole for the split pin S is perpendicular to the flow direction of the
intermittent valve.
19. Use openend spanner A. F. 32 mm to screw in union nut
O and tighten at room temperature with
a torque of 55 Nm.
20. Apply heatresistant lubricant to both sides of the compression spring
P (use e. g. WINIX
®
2150) and
place it onto the union nut O.
21. Use openend spanner A. F. 28 mm to screw the pressure pin
R onto the valve plug D until the
holes for the split pin S in the valve plug and the pressure pin overlap.
22. Insert split pin
S.
23. Reinsert mounting bracket
B and pressure plate V. Align check hole C to the right.
24. Insert hexagonhead cap screws
W and tighten them in diagonally opposite pairs with a torque
of 20 Nm.
25. Put spacer disk
X onto pressure plate V.
26. Screw on diaphragm actuator
Y with a torque of 120 Nm.
27. Attach pressure line for the control fluid of the diaphragm actuator.
28. Operate the valve once.
WINIX
®
2150 is a registered trademark of WINIX GmbH, Norderstedt
TETRABOR
®
is a registered trademark of WackerChemie GmbH, Kempten
Vista de pagina 19