
5 Final Pump Assembly
6.1 Setsealtozerocompression.
Push 101 clamp ring toward the pump impeller until the seal
facesmakecontact.Becertainthat9jamnutsarenottouching
the clamp ring. While holding the faces in contact, screw down
9adjustingnutuntilittouchestheclampring.(SeeFigure7).
Makesurethefacesareinfullcontactbysupportingtheweight
of the assembly at the top of the the clamp ring as well as
on each end near the adjusting nuts. The seal is now at
"zerocompression".Markthepositionoftheadjustingnuts.
SeeFigure8.
8
5.1 Assemble the suction side of the pump casing or liner or suction
cover.
5.2 Adjusttheimpellerclearanceaccordingtomanufacturer's
instructions.
6 Seal Setting Procedure
Zero Compression Figure8
Zero Compression
Comentarios a estos manuales