6
Technical Data
TRG 5-11, TRG 5-41
Type approval
DIN · STW (STB) · 986 98S
EG 01 202 931-B-01 000 7
Service pressure
TRG 5-11: 1 bar g (14.5 psi g)
TRG 5-41: 150 bar g (2176 psi g)
Max. service temperature
TRG 5-11: 1000 °C (1832 °F)
TRG 5-41: 650 °C (1202 °F)
Admissible flow velocities
TRG 5-41: in water 5 m/s
in gases 60 m/s
Connections
TRG 5-11: Protection tube (stop flange or screwed socket optional)
TRG 5-41: Protection weld-in tube
Length of sensor
TRG 5-11: 710 mm nominal length
TRG 5-41: 200 mm length of protection tube
Materials
TRG 5-11: Protection tube made of X 10 CrAl 24 (1.4762)
Screwed sockets made of 9 SMnPb 28 (1.0718)
TRG 5-41: Protection weld-in tube made of X 8 CrNiNb 16-13 (1.4961)
Max. admissible ambient temperature at terminal box
120 °C (248 °F)
Protection of terminal box
IP 54
Temperature sensing element
Thermocouple type K (NiCr-Ni) to DIN IEC 584, class 2.
Weight
TRG 5-11: approx. 1.02 kg at nominal length 710 mm
TRG 5-41: approx. 1.1 kg