CW
Rotation
CCW
Rotation
3
Dimensional Data for X-100 seal, inch
Seal Size
+0.000 A B B C D E F G H J M
-0.002 ±0.001 min. max. min. max. min. (N.P.T.)
* this seal size uses the N-CBR inner seal rotary unit.
† preferred design for these shaft sizes. Use whenever possible.
‡ maximum
1.125 1.000 1.750 1.875 1.78 1.69 2.00 1.02 0.375 2.75 3.75 0.375
*1.250 1.125 1.750 2.000 1.78 1.69 2.00 1.02 0.500 3.00 3.88 0.375
1.375 1.250 2.000 2.125 1.97 1.88 2.00 1.02 0.500 3.12 4.25 0.375
*1.500 1.375 2.000 2.250 1.97 1.88 2.00 1.02 0.375 3.25 4.25 0.375
1.625 1.500 2.250 2.500 1.97 1.88 2.00 1.02 0.375 3.75 4.75 0.375
1.750 1.625 2.375 2.625 1.97 1.88 2.00 1.02 0.500 3.75 4.75 0.375
1.875 1.750 2.500 2.750 1.97 1.88 2.00 1.02 0.500 3.75 5.00 0.375
2.000 1.875 2.625 2.875 1.97 1.88 2.00 1.02 0.500 3.88 5.00 0.375
2.125 2.000 2.750 3.000 1.97 1.88 2.00 1.02 0.625 4 .12 5.12 0.375
2.250 2.125 2.875 3.250 1.97 1.88 2.00 1.02 0.625 4.38 6.00 0.375
2.375 2.250 3.000 3.375 1.97 1.88 2.00 1.02 0.625 4.62 6.50 0.375
2.500 2.375 3.250 3.625 2.16 2.06 2.09 1.11 0.625 5.00 6.38 0.375
2.625 2.500 3.375 3.750 2.16 2.06 2.09 1.11 0.625 5.00 6.62 0.375
2.750 2.625 3.500 3.875 2.16 2.06 2.09 1.11 0.750 5 .75 7.25 0.375
2.875 2.750 3.750 2.16 2.06 2.62 1.58 0.750‡
†3.000 2.750 3.875 2.16 2.06 2.62 1.58 0.750‡
3.000 2.875 3.875 2.16 2.06 2.62 1.58 0.750‡
†3.125 2.875 4.000 2.16 2.06 2.62 1.58 0.750‡
3.125 3.000 4.000 2.16 2.06 2.62 1.58 As 0.750‡
†3.250 3.000 4.125 2.16 2.06 2.62 1.58 0.750‡
3.375 3.125 4.250 2.16 2.06 2.62 1.58 Required 0.750‡
3.500 3.250 4.375 2.28 2.19 2.75 1.71 0.750‡
3.625 3.375 4.500 2.28 2.19 2.75 1.71 0.750‡
3.750 3.500 4.625 2.28 2.19 2.75 1.71 0.750‡
3.875 3.625 4.750 2.28 2.19 2.75 1.71 0.750‡
4.000 3.750 4.875 — 2.28 2.19 2.75 1.71 0.750‡
4.125 3.875 5.000 2.28 2.19 2.75 1.71 0.750‡
X-100 Dimensional Data Figure 2
C
E
D
F
.03"
A
J
4 - G Ø studs equally spaced on HB. C.
Note: Washers may be required for stud
sizes smaller than G
M (N.P.T.)
Outlet
B
Seal
Size
Outlet