2 Disassembly
When disassembling the seal, inspect for conditions which may have caused the
seal to be removed from service. If seal was removed due to premature failure,
determine what conditions caused that failure and correct any problems prior to
returning the repaired seal to service. For assistance with seal failure analysis,
please contact your Flowserve representative.
3 Repair or Replace Guide
Seal parts that are always replaced
• Bellowsassembly[79]
• Stationaryface[14]
• Allgaskets(O-rings)[13],[76],and[19]
• Glandgasket[18]
• Vibrationdampener[183.1]
• Bellowsvibrationdampener[183]
• Settingdevices[103]andcapscrews[40]
• Cup-point[57]andquarter-dogsetscrews[57.1]
• Glandbushing[24]andsnapring[111]
2
1 Nomenclature
Partreferencesinthisdocumentaredenotedinsquareparenthesis,e.g.[79]
O-rings[13]and[76]arethesamesizeandcross-section.
118311183.11310357.140
18197679145241115758
Part Description
Ref.
1 SleeveAssembly
5 DrivePin
11 Gland
13 SeatGasketO-ring
14 StationaryFace
18 GlandGasket
19 SleeveGasketO-ring
24 Glandbushing
40 CapScrew
57 Cup-pointSetScrew
57.1 Quarter-dogSetScrew
58 DriveCollar
76 RotatingFaceGasketO-ring
79 BellowsAssembly
103 SettingDevice
111 SnapRing
183 VibrationDampener
183.1 VibrationDampener