Flowserve VKP 40Ex Manual de usuario Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
7
Technical Data VKP 40Ex, VKP 40
System requirements
Operating system:
Windows 98, 2000, NT 4 (SP6) XP.
CD ROM drive
Minimum requirements
Computer with Pentium
®
compatible processor with 700 MHz
100 MB free hard disk memory
128 MB RAM
800 x 600 screen resolution
Recommended:
Computer with Pentium
®
compatible processor with 1.2 GHz
200 MB free hard disk memory
256 MB RAM
Data collector VKPN 40Ex, VKPN 40
Plastic casing with backlit display. Illumination can be switched on and off.
Illumination switches off automatically after 10 sec. if no key is pressed.
Resolution of graphic display: 128 x 64 pixels.
Membrane keypad with 5 buttons.
Storage capacity sufficient for approx. 600 steam traps allocated to max. 500 test tasks.
Power supplied by two pre-installed Li-Polymer storage batteries, capacity 1800 mAh.
4 hours charging empty battery provides approx. 8 hours operating time.
Max. operating voltage 3.3 V
Max. power consumption 0.25 A
Operating temperature –10 °C to 50°C
Max. admissible service temperature: 50°C
Min. admissible service temperature: –10°C
Degree of humidity: 0 % to 90 % (not condensed)
Protection IP 65
VKPN 40Ex: Approval BVS 04 ATEX E 234
CE 0158 Ex II 2G EEX ib IIC T4
Measuring transducer VKPS 40Ex
Casing made of titanium (3.7035)
Operating temperature –10 °C to 60°C
Measuring range for surface temperature: 0°C to 350°C
Max. admissible service temperature: 60°C
Min. admissible service temperature: –10°C
Power supplied by storage battery of the data collector.
Max. operating voltage 5.0 V
Max. power consumption 0.03 A
VKPS 40Ex: Approved BVS 04 ATEX E 234
CE 0158 Ex II 2G EEX ib II T4
Connecting cable VKPA 40
The connecting cable VKPA 40 consists of the power supply unit with integrated connecting cable and circular plug for connecting the
data collector VKPN 40Ex or VKPN 40 and the connecting cable with a serial connector for connecting the PC. With the power supply
unit connected, the connecting cable connects the equipment with the PC and provides charging of the batteries installed in the data
collector. To adapt the connector to national standards choose a suitable adaptor plug. Remove the adaptor plug from the power supply
unit and attach the appropriate adaptor plug for your country. (Please order separate adaptor for the USA)
Power supply unit: 100 – 240 V / 47 – 63 Hz; output 12 V
Test duration
Min. 10 sec., max. 20 sec.
If the sound level exceeds or falls below the threshold value during a test before 10 seconds have passed, the test procedure wil be
finished after 10 seconds. Otherwise the test takes 20 seconds.
For more information refer to the PC Online Documentation.
Vista de pagina 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 23 24

Comentarios a estos manuales

Sin comentarios