Flowserve TRV5-40 Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
22
Malfunctions
Fault-finding list for TRV 5-40 / NRS 1-40.1 / NRS 1-40.2
Switchpoint max. temp. limit (°C) not exceeded – max. temp. alarm raised.
Fault: Temperature sensor TRG 5-6x defective.
Remedy: Check the readings of the temperature sensor TRG 5-6x (Pt 100). (Basic values of
measuring resistors to DIN 43760 for Pt 100). If the measured values are incorrect replace
the measuring element of the temperature sensor TRG 5-6x.
If faults occur that are not listed above or cannot be corrected, please contact our Technical Services
or the authorized agency in your country.
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 28

Comentarios a estos manuales

Sin comentarios