Flowserve TRV5-40 Manual de usuario Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
6
TRV 5-40
Type approval
TÜV. SWB/SHWS. 03–413
EG BAF-MUC 03 07 103881 004
DIN registry no. STW (STB) 117 906
Input/Output
CAN bus interface with current supply 18 – 36 V DC, short circuit protected
Temperature sensors
TRG 5-63
1x Pt 100 to EN 60751
TRG 5-64
2x Pt 100 to EN 60751
TRG 5-65, TRG 5-66
1x Pt 100 to EN 60751
TRG 5-67
1x Pt 100 to EN 60751
TRG 5-68
2x Pt 100 to EN 60751
Temperature limit T
MAX
(°C) (cut-off temperature)
Min. adjustable limit value: 20°C
Max. adjustable limit value: 650°C
Indicators and adjustors
1 Red three-digit, seven-segment LED display for indicating limit values
1 Green three-digit, seven-segment LED display for indicating the actual value
3 Pushbuttons for limit settings
5 LEDs for internal status messages
1 Code switch with 10 poles for setting the node ID and baud rate
1 Code switch with 10 poles for configuring the system
Internal self-checking routine
Every 10 seconds
Fault response time
30 sec.
Power consumption
2 W
Fuse
Electronic thermal fuse T
MAX
85°C, hysteresis –2K
Protection
IP 65 to EN 60529
Max. admissible ambient temperature
70°C
Technical Data