Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
52
STEP 5
Replace the handwheel adapter (#12-5) with
the handwheel worm gear (#12-1) that is
included in the side-mounted handwheel
adapter kit.
5
12
STEP 6 (MX-20 AND -40 ONLY)
Place the O-ring (#12-4) around the handwheel
adapter; pressing the O-ring into the slot
between the handwheel worm gear adapter
assembly (#12-1) and the actuator housing
(approximately every 15° to 30° until O-ring
seats into slot).
6
12-4
STEP 7
Place the retainer plate (#1-32) on the top of
the actuator housing. Align the mounting taps
and secure with screws (#1-33).
7
1-32
STEP 8
Complete the remounting procedure for side-mounted handwheel assembly #13A (MX-10 and -20)
or #13B (MX-40) as detailed in Section 4.4.3 or Section 4.5.3.