Flowserve MX Limitorque Manual de usuario Pagina 87

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 164
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 86
79
Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
flowserve.com
STEP 3
NOTE: The handwheel adapter for the MX-05 is removed and introduced from the base of the
actuator housing.
Push adapter assembly (#12) from the top
of the actuator out through the bottom of the
actuator housing.
3
Handwheel
Adapter
Assembly 12
4.13.2 Remounting
STEP 4
NOTE: Lightly lubricate quad rings/O-rings before remounting subassemblies.
With handwheel screw taps facing toward the
nameplate side of the actuator, slide handwheel
adapter assembly (#12) into the actuator hous-
ings drive sleeve bore. Use hammer handle
or similar device to push handwheel adapter
assembly against shoulder inside actuator
housing.
4
Handwheel
Adapter
Screw Taps
STEP 5
Once handwheel adapter assembly is installed
in actuator housing, wind wave spring (#1-10)
into groove on the handwheel adapter.
5
1-10
Vista de pagina 86
1 2 ... 82 83 84 85 86 87 88 89 90 91 92 ... 163 164

Comentarios a estos manuales

Sin comentarios