Vista de pagina 67
MX/QX HART Field Unit FCD LMENIM2340-00 – 1/14
68
Command Response Code
No. Description Code Class Description
71 Lock Device 0
1-4
5
6
7-9
10
11
12-15
16
17-31
32
33
34
35
36
37-127
Success
N/A
Error
Error
N/A
Error
Error
N/A
Error
N/A
Error
Error
Error
Error
Error
N/A
No Command-Specific Errors
Undefined
Too Few Data Bytes Received
Device-Specific Command Error
Undefined
Invalid Lock Code
Cannot Lock Device
Undefined
Access Restricted
Undefined
Busy
DR Initiated
DR Running
DR Dead
DR Conflict
Undefined
76 Read Lock Device State 0
1-5
6
7-15
16
17-31
32
33-127
Success
N/A
Error
N/A
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Device-Specific Command Error
Undefined
Access Restricted
Undefined
Busy
Undefined
78 Read Aggregated Commands 0
1
2
3-4
5
6
7
8
9
10-29
30
31
32
33
34
35
36
37-127
Success
N/A
Error
N/A
Error
Error
N/A
Warning
Error
N/A
Warning
N/A
Error
Error
Error
Error
Error
N/A
No Command-Specific Errors
Undefined
Invalid Selection
Undefined
Too Few Data Bytes Received
Device-Specific Command Error
Undefined
Update Failure
Invalid Command Request
Undefined
Command Response Truncated – One or more commands are
dropped in the response
Undefined
Busy
DR Initiated
DR Running
DR Dead
DR Conflict
Undefined
79 Command 79 Write Device
Variable
0
1
2
3-4
5
6
7
8
9
10
11-13
14
15
16
17
18
19
20-31
32
33
34
35
36
37-127
Success
N/A
Error
N/A
Error
Error
Error
Warning
N/A
Error
N/A
Warning
N/A
Error
Error
Error
Error
N/A
Error
Error
Error
Error
Error
N/A
No Command-Specific Errors
Undefined
Invalid Selection
Undefined
Too Few Data Bytes Received
Device-Specific Command Error
In Write Protect Mode
Device Family Status Bits Not Set
Undefined
Invalid Write Device Variable Command Code
Undefined
Requested value was returned in command response but Rate-of-
Change limit was exceeded. Device Variable Tracking to value written
at maximum rate allowed.
Undefined
Access Restricted
Invalid Device Variable Index
Invalid Units Code
Device Variable Index not allowed for this command
Undefined
Busy
DR Initiated
DR Running
DR Dead
DR Conflict
Undefined
89 Set Real Time Clock 0
1
2
3
4
5
6
7
8-15
16
17-127
Success
N/A
Error
Error
N/A
Error
Error
Error
N/A
Error
N/A
No Command-Specific Errors
Undefined
Invalid Selection (Time-set code)
Passed Parameter Too Large
Undefined
Too Few Data Bytes Received
Device-Specific Command Error
In Write Protect Mode
Undefined
Access Restricted
Undefined
90 Read Real Time Clock 0
1-5
6
7-127
Success
N/A
Error
N/A
No Command-Specific Errors
Undefined
Device-Specific Command Error
Undefined
Vista de pagina 67